Tk Series Synchronous Motor for Drive Compressors and Pumps Tk4000-16 2600 4000kw 10kv IP20

Tk Series Synchronous Motor for Drive Compressors and Pumps Tk4000-16 2600 4000kw 10kv IP20

I. Overview
The big three-stage synchronous motor for TK collection air compressor is a higher-performance collection merchandise specifically created and produced by our business for the load of air compressor.
This collection of motors adopts new technology, new materials, new procedures, exquisite content choice, and refined manufacturing. It has the attributes of small dimensions, gentle excess weight, gorgeous visual appeal, large performance, low sound, minimal vibration, secure and reputable operation, and handy use and maintenance.

two. Implementation standards
GB755 Rotating Motor Score and Performance
Classification of GB/T997 rotary motor structure type, installation sort and junction box placement (IM code)
GB/T1571 Three-section synchronous motor examination approach
GB/T1993 Rotating Device Cooling Method
GB/T4942.1 Safety course (IP) classification of the total structure of rotating electrical equipment
GB/T10068 The measurement, analysis and limit of mechanical vibration with a shaft heart peak of 56mm and over
GB/T10069 Rotating Equipment Sounds Measurement Strategy and Limit
JB/T8667.one CZPT Problems of Large 3-stage Synchronous Motor Component 1: TK Sequence
three. Simple complex parameters

Electrical power variety: 250~10000KW
Rated voltage: 6000, 10000V
Rated speed: 250, 273, three hundred, 333, 375, 428, 500, 600r/min
Rated frequency: 50HZ
Defense amount: IP00, IP20, IP23, IP44
Insulation class: F
Quota: SI
Cooling strategy: IC01, IC37, IC81W
Installation method: IM7311, IM5710, IM7312, IM7315
*Can be produced in accordance to other parameters in accordance to user needs
4, technical qualities

4.one The structural layout is affordable, protected and trustworthy, and the capability to step out of step is strong.
four.two The major insulation composition employing new insulating materials has large voltage resistance and long motor lifestyle.
four.3 The temperature increase margin is huge. The motor adopts F-course insulation, and the temperature increase is assessed in accordance to the temperature rise limit of the B pole insulation.
4.four The protection unit is advanced and full.
four.one.1 The stator windings and bearings are outfitted with temperature detection devices, which can detect, alarm and journey.
four.four.2 Shutdown place heater with anti-condensation impact.
4.five Massive inertia. Motors with distinct times of inertia can be produced in accordance to user requirements.
5, structure sort

five.1 The overall composition of this collection of motors is welded with steel plates for the body, end cover, and base plate. The motor is an unbiased cavity, and the slip ring can be made with different defense levels according to person demands.
five.two Stator: The stator frame is welded by metal plate. The motor stator outlet is led out by a higher-voltage rubber cable. The outlet position can be led out from the reduce part of the base or from the primary junction box on the facet of the motor.
The stator core is superimposed by low-loss silicon steel sheets, and the main sections are divided by radial ventilation ducts.
The stator winding is F quality insulation, and the temperature rise is assessed according to B quality to aid lengthen the services lifestyle. It adopts VPI general dipping paint therapy, which has higher electrical performance, mechanical energy, insulation overall performance, humidity resistance and thermal steadiness.
five.three The rotor magnetic pole main is produced of laminated metal plates, and has various structures this kind of as magnetic pole screws and T tails. The rotor bracket has air flow holes and is geared up with a enthusiast, which can properly control the temperature rise of the rotor.
5.four Adopt seat kind spherical sliding bearing. The bearings are insulated to avoid shaft currents.
Use new lubricating oil and slender-walled bearing alloy tiles, and established electromagnetic centerline indications.
five.5 According to consumer needs, the slip ring can be made as a constructive strain ventilation composition to boost the basic safety of the motor. The overall length of the motor with the constructive stress ventilation construction of the slip ring is marginally elevated.
6. Circumstances of Use
six.1 Voltage fluctuation: ±5% (It can operate underneath ±10% under the problems of 7.3 in GB755)
six.two Frequency fluctuation: ±2%
6.3 The altitude does not exceed 1000m
6.four The greatest ambient temperature does not exceed +40ºC, and the minimum is 0ºC.
7, product description
 TK1250-sixteen/2150

Outer diameter of stator punch (Φ2150mm)

Amount of poles (sixteen poles)

Rated electricity (1250KW)
A few-section synchronous motor for compressor
eight. Ordering guidelines
eight.one Prior to positioning an order, please refer to the product catalog of this collection to explain the necessary product design, specifications and other information. If there is a discrepancy among the specifications and the samples, remember to speak to our company.
eight.2 The motor model, rated electricity, synchronous speed, rated voltage, rated frequency, security amount, moment of inertia, rotation path, set up variety, and so forth. should be indicated when purchasing.
eight.3 The sample complex knowledge sheet only lists the related data of motors with rated voltages of 6KV and 10KV. If consumers need to have other voltage levels, our company can also provide appropriate technological knowledge when buying.
8.four The technical knowledge and dimensions in the sample are only for reference when the user selects the product. The formal information will be supplied by the business right after the agreement or specialized agreement is signed.
eight.5 If there are any other unique requirements, make sure you give the demands and signal the pertinent specialized settlement when buying.